AMT02 Water Proof
Conductivity/TDS/Salt/Temp
Meter ![]() |
Technical Data: Range: Conductivity: 0-2000uS; 2.00-20.00mS TDS: 0-1300ppm, 1.30-13.00ppt Salt: 0-1000ppm; 1.00-12.00ppt Temperature: 0-90°C Accuracy: Conductivity, TDS, Salt: ±2% F.S. Temp: ±0.2°C + 1digit Resolution: Cond.: 1uS/0.01mS; TDS: 1ppm/0.01ppt; Salt: 1ppm/0.01ppt; Temp: 0.1°C ATC: Cond/TDS/Salt: 0-50°C Power: DC1.5V x 4 battery size: AAA/UM-4 |
|
Pen Type pH/ Meter
![]() |
|
||||||
Features: Auto calibration, Auto identification of standard solutions, Auto power-off, low voltage alarm, Auto temperature compensation, Auto switches of range, IP57 dustproof and waterproof |
||||||
Model |
PE01 | PE02 | PE03 | PE05 | PE06 | PE07 |
Description |
pH Meter | Conductivity Tester | TDS Meter | ORP Meter | Salinity Meter | Sea Water |
Range |
0~14.0pH |
0~100.0μS/cm 0~1000μS/cm 0~10.00mS/cm |
0~50.0 ppm 0~500 ppm 0~5.00 ppt |
±1000mV | 0~5.00ppt | 0~100.0ppt |
Resolution | 0.1pH | 0.1/1μS/cm; 0.01mS/cm | 0.1/1ppm; 0.01ppt | 1mV | 0.01ppt | 0.01/0.1ppt |
Accuracy | ±0.2pH | ±1%FS | ±1%FS | ±0.5%FS | ±1%FS | ±1.5%FS |
Calibration Solution |
YES |
NO | YES | |||
Power | AAA batteries×2,1.5V×2 | |||||
Dimension | 39×25×176 mm |
KL-732 Dual Conductivity
TDS Meter
![]() |
Measuring Range: 0-9999
uS/cm, 0-4999ppm Temp Range: 0-99°C (32-212˚F) Resolution: 1 uS/cm, 1ppm, 0.1°C Display: 4 digit LCD with backlight Accuracy: ±2% FS Data Hold Backlight: 0-40ppm green colour for direct drink, up 40ppm red light Size: 165 x 28 x 13mm Weight: 41g |
|
KL-733 Dual Conductivity
TDS Meter
![]() |
Measuring Range: 0-9999
uS/cm, 0-4999ppm Temp Range: 0-99°C (32-212˚F) Resolution: 1 uS/cm, 1ppm, 0.1°C Display: 4 digit LCD with backlight Accuracy: ±2% FS Data Hold Backlight: 0-40ppm green colour for direct drink, up 40ppm red light Size: 165 x 28 x 13mm Weight: 41g |
|
KL-1388 Conductivity Meter
![]() |
Measuring Range: 0-1999
uS/cm Resolution: 1 uS/cm Display: 4 digit LCD Accuracy ±2% FS Temp 5 - 50°C (ATC) Size 150 x 32 x 16 mm Weight: 54g |
|
KL-1382 Serials Conductivity
Meter
![]() |
Order No.: KL-1382P (Platinum Probe) KL-1382S (Stainless Steel Probe) 1.Measuring range:0~1999μs/cm 2.Resolution: 1μs/cm 3.Accuracy: ±2%F.S 4.Operating Temperature: 0℃- 50℃ 5.Power Supply: 2×3V(CR2032 Battery) 6.Display:4-digital LCD 7.Environment:Humidity:≤95% 8.Weight:46g 9.Dimension:150mm×27mm×20mm |
|
KL-138C Serials Conductivity
Meter
![]() |
Order No.: KL-138CP (Platinum Probe) KL-138CS (Stainless Steel Probe) Technical Specification: Model Measuring range: 100~19900us/cm Accuracy: ±2% F.S Resolution: 100us/cm Automatic Temperature Compensation: 0℃~50℃ Power Supply: 4×1.5V(AG13) Dimensions: 150mm×29mm×15mm Weight: 51g |
|
KL-1382A & KL-1382B Conductivity
Meter
![]() |
Model | KL-1382A | KL-1382B |
Measuring range | 0~1999us/cm | |
Accuracy | ±2% F·S | |
Resolution | 1us/cm | |
Display | 4-digital LCD | |
Environment | Humidity:≤95% | |
ATC | 0℃~50℃ | |
Power Supply | 4×1.5V(AG13) | |
Dimensions | 165×26×26(mm3) | 60×55×23(mm3) |
Weight | 63g | 60g |
|
Order No.: KL-1382B (Normal Battery) KL-1382BA (Adaptor + Rechargeable Battery) |
|
![]() |
KL-1383 Conductivity Meter
![]() |
Order No.: KL-1383P (Platinum Probe) KL-1383S (Stainless Steel Probe) Measuring range: 0~19.99ms/cm Accuracy: ±2%F·S Resolution: 0.01ms/cm Display: 4-digit LCD Environment Humidity: ≤95% Automatic Temperature Compensation: 0℃~50℃ Power Supply: 2×3V(CR2032 Battery) Dimensions: 150×27×20(mm3) Weight: 46g |
|
Conductivity/TDS Meter
![]() |
Model |
HMT-1 | HMT-2 | HMT-3 | HMT-4 | HMT-5 |
![]() |
Range |
0~9990ppm
|
0~9990ppm
0~ |
0~9990us/cm
|
0~9990us/cm
0~ |
0~9990ppm;0~9990us/cm
0~ |
|
Accuracy |
±2%F.S
|
|||||
A T C |
0 ~
|
|||||
Auto Shut-off |
10 minutes
|
|||||
Power |
2×1.5v(LR44l)
|
|||||
Dimensions |
142×25×
|
|||||
Weight |
|
Conductivity Tester EC-3
![]() |
Ideal for all water
purification applications, wastewater regulation, aquaculture,
hydroponics, and colloidal silver. Perfect for both consumer or
commercial use. Carry one in your pocket or toolbox at all times! Features •Ideal for commercial use. Includes a carrying case with belt clip. •Highly efficient and accurate due to its advanced microprocessor technology. •Hold Function: saves measurements for convenient reading and recording. •Auto-off function: the meter shuts off automatically after 10 minutes of non-use to conserve batteries. •Measurement Range: 0-9990µS. From 0-999µS, the resolution is in increments of 1µS. From 1000 to 9990µS, the resolution is in increments of 10µS, indicated by a blinking 'x10' image. •Built-in digital thermometer •Display: large and easy-to-read LCD screen. •Factory Calibrated: our meters are calibrated with a 700µS NaCl solution. Meters can be recalibrated with a mini-screwdriver. Specifications EC Range: 0 - 9990µS (µS/cm) Temp. Range: 0 - 80 degrees Celsius Resolution: 1µS; 10 µS, 0.1 degree Celsius Accuracy: +/- 2% ATC: Built-in sensor for 1 to 50°C (33 to 122°F) Power source: 2 x 1.5V button cell batteries Dimensions: 15.5 x 3.1 x 2.3cm (6.1 x 1.25 x 1 inches) Weight with case: 76.5g (2.7 oz) Weight without case: 56.7g (2 oz) |
|
Conductivity Tester EC-3M
![]() |
Ideal for all water
purification applications, wastewater regulation, aquaculture,
hydroponics, and colloidal silver. Perfect for both consumer or
commercial use. Carry one in your pocket or toolbox at all times! Features •Ideal for commercial use. Includes a carrying case with belt clip. •Highly efficient and accurate due to its advanced microprocessor technology. •Hold Function: saves measurements for convenient reading and recording. •Auto-off function: the meter shuts off automatically after 10 minutes of non-use to conserve batteries. •Measurement Range: 0.00-9.99ms/cm. From 9.99ms/cm, the resolution is in increments of 0.001ms/cm. From 1 to 9.99ms/cm, the resolution is in increments of 0.01ms/cm, indicated by a blinking 'x10' image. •Built-in digital thermometer •Display: large and easy-to-read LCD screen. •Factory Calibrated: The EC-3M has been factory calibrated to a 1.413ms/cm KCl solution. Meters can be recalibrated with a mini-screwdriver. Specifications EC Range: 0 ~ 9.99ms/cm Temp. Range: 0 ~ 80 degrees Celsius Resolution: 0~9.99: 0.001ms; 1~9.99: 0.01ms (indicated by a 'x10' icon) Temperature Resolution: 0.1 degree Celsius (Celsius only) Accuracy: +/-2% ATC: Built-in sensor for Automatic Temperature Compensation of 1 to 50°C (33 to 122o °F) Power source: 2 x 1.5V button cell batteries (included) (LR44 or equivalent) Battery life: 1000 hours of usage Dimensions: 15.5 x 3.1 x 2.3cm (6.1 x 1.25 x 1 inches) Weight with case: 76.5g (2.7 oz) Weight without case: 56.7g (2 oz) To convert mS (milli-Siemens) to µS (milli-Siemens): multiply by 1000. 1mS = 1000 µS |
|
KL-1383A & KL-1383B Conductivity
Meter
![]() |
Model | KL-1383A | KL-1383B |
Measuring range | 0~19.99ms/cm | |
Accuracy | ±2% F·S | |
Resolution | 0.01ms/cm | |
Display | 4-digital LCD | |
Environment | Humidity:≤95% | |
ATC | 0℃~50℃ | |
Power Supply | 4×1.5V(AG13) | |
Dimensions | 165×26×26(mm3) | 60×55×23(mm3) |
Weight | 63g | 60g |
Order No.: |
Order No.: KL-1383B (Normal Battery) KL-1383BA (Adaptor + Rechargeable Battery) |
|
|
|
KL-1386 Conductivity Meter with
Temp
![]() |
Order
No.: |
![]() |
||
KL-1386 | μs/cm | Temp | |
Measuring range | 0~1999μs/cm | -50℃~70℃ | |
Resolution | 1μs/cm | 0.1℃ | |
Accuracy | ±2℅F·S | ±1℃ | |
Display | 4-digital LCD | ||
Environment | Humidity:≤95℅ | ||
ATC | 0℃~50℃ | ||
Power Supply | 4×1.5V(AG13) | ||
Dimensions | 170×36×23mm3 | ||
Weight | 98g |
KL-13836 Conductivity Meter with
Temp
![]() |
Order
No.: |
![]() |
||
KL-13836 | ms/cm | Temp | |
Measuring range | 0~19.99ms/cm | -50℃~70℃ | |
Resolution | 0.01ms/cm | 0.1℃ | |
Accuracy | ±2% F·S | ±1℃ | |
Display | 4-digital LCD | ||
Environment | Humidity:≤95℅ | ||
ATC | 0℃~50℃ | ||
Power Supply | 4×1.5V(AG13) | ||
Dimensions | 170×36×23mm3 | ||
Weight | 98g |
Waterproof Conductivity Tester
![]() |
CD20 is used to measure low conductivity liquids, E.g. Pure water, Distilled water etc; CD30 is used to measure general conductivity liquids. E.g. Tap water, Table-water etc; CD40 is used to measure high conductivity liquids. E.g. Waste water, Salt water etc. |
Waterproof: The meter with good waterproof performance, It can float when sink in water. |
Model | CD20 | CD30 | CD40 |
![]() |
Conductivity Range | 0.0~199.9uS/cm | 0~1999uS/cm | 0.00~19.99mS/cm | |
Conductivity Accuracy | ±1% F.S | ±1% F.S | ±1% F.S | |
Resolution | 0.1uS/cm | 1uS/cm | 0.01mS/cm | |
Calibration Points | 2 Points | |||
Calibration Solutions | 146.6uS/cm | 1408uS/cm | 12.85mS/cm | |
Temp Coefficient | 2%/oC | |||
Auto-Off | 8 minutes after last key pressed | |||
Hold Function | Yes | |||
Non-Volatile Memory | Yes | |||
Operating Temperature | 0~60oC | |||
Power Requirements | 3×1.5V alkaline button cell batteries | |||
Battery Life | Approx. 150 hours of continuous use | |||
Dimensions | 180(L)mm×30(Dia.)mm | |||
Weight | 85g |
Low
Range Conductivity
Tester CD10L
![]() |
Applications: • Pure water and drinking water • Education and other industrial applications |
|
Features: • Low range pocket conductivity tester is equipped with a standard platinum sensor. • 1 point push-button calibration allows using the custom calibration solutions. • Automatic temperature compensation provides accurate reading over the entire range. • Hold function freezes current reading for easy viewing and recording. • Auto-Power Off helps user effectively conserve battery life. • Replaceable electrode module reduces maintenance and replacement cost. • Waterproof feature to ensure complete protection in harsh environment. |
|
Specifications: 1. Range: 1.0~199.9µS/cm 2. Accuracy: ±1% F.S. 3. Calibration Points: 1 point 4. Calibration Solutions: 146.5µS/cm 5. Temperature Compensation: 0~50°C 6. Temperature Coefficient: 2%/°C 7. Cell Constant: K=1 8. Normalization Temperature: 25°C 9. Hold Function: Manual 10. Power Off: Manual or Automatic (8 minutes after last key pressed) 11. Operating Temperature: 0~60°C, 32~140°F 12. Power Requirements: 3×1.5V "G13A" Batteries 13. Dimensions: 185(L)×40(Dia.)mm 14. Weight: 100g |
Middle Range Conductivity
Tester CD10M
![]() |
Applications: • Water and wastewater treatment • Swimming pools and aquariums • Aquaculture and hydroponics • Beverage industry and other industrial applications |
|
Features: • Mid range pocket conductivity tester is equipped with a standard platinum sensor. • 1 point push-button calibration allows using the custom calibration solutions. • Automatic temperature compensation provides accurate reading over the entire range. • Hold function freezes current reading for easy viewing and recording. • Auto-Power Off helps user effectively conserve battery life. • Replaceable electrode module reduces maintenance and replacement cost. • Waterproof feature to ensure complete protection in harsh environment. |
|
Specifications: 1. Range: 10~1999µS/cm 2. Accuracy: ±1% F.S. 3. Calibration Points: 1 point 4. Calibration Solutions: 1413µS/cm 5. Temperature Compensation: 0~50°C 6. Temperature Coefficient: 2%/°C 7. Cell Constant: K=1 8. Normalization Temperature: 25°C 9. Hold Function: Manual 10. Power Off: Manual or Automatic (8 minutes after last key pressed) 11. Operating Temperature: 0~60°C, 32~140°F 12. Power Requirements: 3×1.5V "G13A" Batteries 13. Dimensions: 185(L)×40(Dia.)mm 14. Weight: 100g |
High Range Conductivity
Tester CD10H
![]() |
Applications: • Water and wastewater treatment • Electroplating and printing industry • Aquaculture and hydroponics • Aquarium and other industrial applications |
|
Features: • High range pocket conductivity tester is equipped with a standard platinum sensor. • 1 point push-button calibration allows using the custom calibration solution. • Automatic temperature compensation provides accurate reading over the entire range. • Hold function freezes current reading for easy viewing and recording. • Auto-Power Off helps user effectively conserve battery life. • Replaceable electrode module reduces maintenance and replacement cost. • Waterproof feature to ensure complete protection in harsh environment. |
|
Specifications: 1. Range: 0.1~19.99mS/cm 2. Accuracy: ±1% F.S. 3. Calibration Points: 1 point 4. Calibration Solutions: 12.88mS/cm 5. Temperature Compensation: 0~50°C 6. Temperature Coefficient: 2%/°C 7. Cell Constant: K=1 8. Normalization Temperature: 25°C 9. Hold Function: Manual 10. Power Off: Manual or Automatic (8 minutes after last key pressed) 11. Operating Temperature: 0~60°C, 32~140°F 12. Power Requirements: 3×1.5V "G13A" Batteries 13. Dimensions: 185(L)×40(Dia.)mm 14. Weight: 100g |
Pocket Conductivity
Tester CD20T
![]() |
Applications: • Water and wastewater treatment • Research and education • Environmental monitoring • Electroplating and printing industry • Aquaculture and hydroponics • Beverage industry and other industrial applications |
|
Features: • Multi-range pocket conductivity meter covers the low, mid, high ranges. • Standard platinum sensor provides fast and reliable measuring results. • 1 to 3 points push-button calibration with automatic calibration solution recognition. • Automatic temperature compensation ensures accurate reading over the entire range. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Battery indicator shows the remaining battery capacity. • Auto-Power Off helps user effectively conserve battery life. • System menu allows setting the 5 parameters, including the number of calibration points, temperature unit, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Replaceable electrode module reduces maintenance and replacement cost. • Waterproof feature to ensure complete protection in harsh environments. |
|
Specifications: Conductivity: 1. Range: 0~20.00, 200.0, 2000µS/cm, 20.00mS/cm 2. Accuracy: ±1% F.S. 3. Resolution: 0.01, 0.1, 1 4. Calibration Points: 1 to 3 points 5. Calibration Solutions: 84µS/cm, 1413µS/cm, 12.88mS/cm Temperature: 1. Range: 0~60°C, 32~140°F 2. Accuracy: ±1°C 3. Resolution: 0.1°C, 0.1°F 4. Calibration Points: 1 point 5. Calibration Range: Measured value ±10°C Others: 1. Temperature Compensation: 0~60°C, 32~140°F 2. Temperature Coefficient: 2%/°C 3. Cell Constant: K=1 4. Normalization Temperature: 25°C 5. Hold Function: Manual or Automatic 6. Power Off: Manual or Automatic (8 minutes after last key pressed) 7. Reset Function: Yes 8. Power Requirements: 2×1.5V "AAA" Batteries 9. Dimensions: 185(L)×40(Dia.)mm 10. Weight: 100g |
Pocket Conductivity
TDS Tester CD30T
![]() |
Applications: • Water and wastewater treatment • Research and education • Environmental monitoring • Electroplating and printing industry • Aquaculture and hydroponics • Beverage industry and other industrial applications |
|
Features: • Multi parameter pocket conductivity meter contains TDS measurement mode. • Standard platinum sensor provides fast and reliable measuring results. • Adjustable TDS conversion factor for different measurement requirements. • 1 to 3 points push-button calibration with automatic calibration solution recognition. • Automatic temperature compensation ensures accurate reading over the entire range. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Battery indicator shows the remaining battery capacity. • Auto-Power Off helps user effectively conserve battery life. • System menu allows setting the 6 parameters, including the number of calibration points, TDS factor, temperature unit, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Replaceable electrode module reduces maintenance and replacement cost. • Waterproof feature to ensure complete protection in harsh environments. |
|
Specifications: Conductivity: 1. Range: 0~20.00, 200.0, 2000µS/cm, 20.00mS/cm 2. Accuracy: ±1% F.S. 3. Resolution: 0.01, 0.1, 1 4. Calibration Points: 1 to 3 points 5. Calibration Solutions: 84µS/cm, 1413µS/cm, 12.88mS/cm TDS: 1. Range: 0~10ppt (Max. 20ppt, depending on factor setting) 2. Accuracy: ±1% F.S 3. TDS Factor: 0.1~1.0 (Default 0.5) Temperature: 1. Range: 0~60°C, 32~140°F 2. Accuracy: ±1°C 3. Resolution: 0.1°C, 0.1°F 4. Calibration Points: 1 point 5. Calibration Range: Measured value ±10°C Others: 1. Temperature Compensation: 0~60°C, 32~140°F 2. Temperature Coefficient: 2%/°C 3. Cell Constant: K=1 4. Normalization Temperature: 25°C 5. Hold Function: Manual or Automatic 6. Power Off: Manual or Automatic (8 minutes after last key pressed) 7. Reset Function: Yes 8. Power Requirements: 2×1.5V "AAA" Batteries 9. Dimensions: 185(L)×40(Dia.)mm 10. Weight: 100g |
Pocket Conductivity
TDS Salinity Tester CD40T
![]() |
Applications: • Water and wastewater treatment • Research and education • Environmental monitoring • Electroplating and printing industry • Aquaculture and hydroponics • Beverage industry and other industrial applications |
|
Features: • Multi parameter pocket conductivity meter is equipped with a dual display LCD. • Standard platinum sensor provides fast and reliable measuring results. • Adjustable TDS conversion factor to meet different measurement requirements. • 1 to 3 points push-button calibration with automatic calibration solution recognition. • Automatic temperature compensation ensures accurate reading over the entire range. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Battery indicator shows the remaining battery capacity. • Auto-Power Off helps user effectively conserve battery life. • System menu allows setting 6 parameters, including the number of calibration points, temperature unit, hold function, auto-power off, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Replaceable electrode module reduces maintenance and replacement cost. • Waterproof feature to ensure complete protection in harsh environments. |
|
Specifications: Conductivity: 1. Range: 0~20.00, 200.0, 2000µS/cm, 20.00mS/cm 2. Accuracy: ±1% F.S 3. Resolution: 0.01, 0.1, 1 4. Calibration Points: 1 to 3 points 5. Calibration Solutions: 84µS/cm, 1413µS/cm, 12.88mS/cm TDS: 1. Range: 0~10ppt (Max. 20ppt, depending on factor setting) 2. Accuracy: ±1% F.S 3. TDS Factor: 0.1~1.0 (Default 0.5) Salinity: 1. Range: 0~10ppt 2. Accuracy: ±1% F.S 3. Resolution: 0.01ppt Temperature: 1. Range: 0~60°C, 32~140°F 2. Accuracy: ±1°C 3. Resolution: 0.1°C, 0.1°F 4. Calibration Points: 1 point 5. Calibration Range: Measured value ±10°C Others: 1. Temperature Compensation: 0~60°C, 32~140°F 2. Temperature Coefficient: 2%/°C 3. Cell Constant: K=1 4. Normalization Temperature: 25°C 5. Hold Function: Manual or Automatic 6. Power Off: Manual or Automatic (8 minutes after last key pressed) 7. Reset Function: Yes 8. Power Requirements: 2×1.5V "AAA" Batteries 9. Dimensions: 185(L)×40(Dia.)mm 10. Weight: 100g |
KL-1387
Waterproof Conductivity
and Temperature Meter
![]() |
Technical Specification:
μs/cm | Temp(℃) |
![]() |
|
Measuring range |
0~19990μs/cm | -50℃~70℃ | |
Resolution |
10μs/cm | 0.1℃ | |
Accuracy |
±2% F·S | ±1℃ | |
Display |
4-digital LCD | ||
Environment |
Humidity:≤95% | ||
Automatic Temperature Compensation |
0℃~50℃ | ||
Power Supply |
4×1.5V(AG13) | ||
Dimensions |
188mm×35mm×35mm | ||
Weight |
98g |
Professional CON900
Conductivity/TDS/Salinity/Resistivity Meter
![]() |
This meter is a perfect combination with the most advanced electronic technology, sensor technology and software design. The meter can measure the parameters of conductivity, TDS, salinity, resistivity, and temperature for high accuracy water solution. It is the best portable conductivity meter with the highest performance and the lowest cost. It is suitable for the trade such as the mining industry, power plant, water treatment projects and environmental protection, etc., especially has more extensive application in the field and spot test. |
|
Measuring range |
Conductivity: 0.00~19.99μS/cm; 20.0~199.9μS/cm; 200~1999μS/cm; 2.00~19.99mS/cm; 20.0~199.9mS/cm TDS: 0~100g/L Salinity: 0~100ppt Resistivity: 0~100MΩ·cm |
Resolution |
0.01/0.1/1μS/cm; 0.01/0.1mS/cm |
Accuracy |
Meter:±1.0% FS, meter with electrode:±1.5% FS |
Temp. Compensation |
0 ~ 50℃ (automatic) |
Electrode constant |
0.1/1/10cm-1 |
Benchmark temperature |
25℃, 20℃and 18℃ |
Data storage |
100groups |
Storage content |
Series number, measuring value, unit and temp. |
Power |
Two AA batteries (1.5V x2) |
Size and weight |
Meter:65×120×31mm/180g; Carrying case:255 x 210x 50mm/790g |
Quality Safety Certificate |
ISO9001:2000, CE and CMC |
Environment Temp. |
5 ~ 35℃ (0.01grade) |
Environmental Humidity |
≤85% |
IP Rating |
IP57 Dustproof and waterproof |
10 IN 1 pH/mV Conductivity/TDS/DO
Meter EC910 (Chinese Probe) EC910X (UK Probe) ![]() |
Features: High accuracy multi parameter water quality meter includes 8 measurement modes, the meter is suitable for measuring the pH, ORP, Ion concentration, Conductivity, TDS, Salinity, Resistivity and Dissolved Oxygen of the liquids. |
|
pH Mode: • High accuracy portable multi parameter water quality meter is equipped with a large backlit LCD display. • 1 to 5 points push-button calibration with auto-buffer recognition. • Selectable pH buffer standards (USA/NIST/DIN) or using the custom calibration solutions. • Automatic electrode slope display helps user decide whether to replace sensor. |
|
ORP Mode: • Single point offset calibration allows adjusting the displayed value to a known standard. • Relative and absolute millivolt measurement modes provide accurate ORP readings. |
|
Ion Mode: • 2 to 5 points calibration including the eight concentration calibration points can be selected. • Automatically recognize ion selective electrodes, does not need to specify type of ion. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units including the ppm, mg/L and mol/L. |
|
Conductivity/TDS/Salinity/Resistivity Mode: • 1 to 5 points push-button calibration with automatic calibration solution recognition. • Selectable cell constants (0.1/1/10), normalization temperatures (20/25°C), TDS conversion factors, seawater and practical salinity measurement modes. |
|
Dissolved Oxygen Mode: • 1 or 2 points calibration using air-saturated water and zero oxygen solution. • Manual salinity and barometric pressure compensation improve the measurement accuracy. |
|
Other Features: • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration corrects temperature deviation. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows setting the 15 parameters, including the calibration points, resolutions, stability conditions, measurement units, etc. • Reset feature automatically resumes all parameters back to factory default options. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that use the meter smoothly. |
Specifications: |
1. pH |
•Range: -2.000~20.000pH •Accuracy: ±0.002pH •Resolution: 0.1, 0.01, 0.001pH •Calibration Points: 1 to 5 points, USA, NIST, DIN Standards •Temperature Compensation: 0~100°C, 32~212°F, Manual or Automatic |
2. mV |
•Range: -1999.9~1999.9mV •Accuracy: ±0.2mV •Resolution: 0.1, 1mV •Calibration Points: 1 point (Only for Relative mV mode) •Calibration Range: ±200mV |
3. Ion |
•Range: 0.001~19999ppm,
mg/L, mol/L (Depending on range of ISE) •Accuracy: ±0.5% F.S (Monovalent), ±1% F.S (Divalent) •Resolution: 0.001, 0.01, 0.1, 1 •Calibration Points: 2 to 5 points •Calibration Solutions: 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L |
4. Conductivity |
•Range: 0~20.00, 200.0,
2000µS/cm, 20.00, 200.0mS/cm •Accuracy: ±0.5% F.S •Calibration Points: 1 to 5 points •Calibration Solutions: 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm •Temperature Compensation: 0~100°C, 32~212°F, Manual or Automatic •Temperature Coefficient: 0.0~10.0%/°C •Compensation Modes: Linear or Pure Water •Cell Constant: K=0.1, 1, 10 •Normalization Temperature: 20 or 25°C |
5. TDS |
•Range: 0~10ppt (Max.
20ppt, depending on factor setting) •Accuracy: ±1% F.S •TDS Factor: 0.1~1.0 (Default 0.5) |
6. Salinity |
•Range: 0~10ppt (Max.
80ppt) •Accuracy: ±1% F.S •Measurement Modes: Seawater or Practical Salinity |
7. Resistivity |
•Range: 0~100MΩ •Accuracy: ±1% F.S •Resolution: 0.01, 0.1, 1 |
8. Dissolved Oxygen (DO) |
•Range: 0.00~20.00mg/L (or
ppm) •Accuracy: ±0.2mg/L •Resolution: 0.01mg/L •Calibration Points: 1 or 2 points •Temperature Compensation: 0~50°C, 32~122°F •Pressure Correction: 60.0~112.5kPa, 450~850mmHg •Salinity Correction: 0~50g/L |
9. Saturation of Oxygen |
•Range: 0.0~200.0% •Accuracy: ±2.0% •Resolution: 0.1% |
10. Temperature |
•Range: 0~105°C, 32~221°F •Accuracy: ±0.5°C, ±0.9°F •Resolution: 0.1°C •Calibration Points: 1 point •Calibration Range: Measured value ±10°C |
11. Others |
Hold Function: Manual or
Automatic Stability Conditions: Low or High Calibration Due: 0 to 31 days Power Off: Manual or Automatic (10, 20, 30 minutes) Reset Function: Yes Memory: Stores up to 500 data sets Output: USB Communication Interface Connector: BNC, 6-pin Mini Plug Power Requirements: 3 x 1.5V "AA" Batteries Battery Life: Approximately 150 hours (Turn off the backlit) Dimensions: 170(L)x 85(W) x 30(H)mm Weight: 300g |
CD5 Series Portable
Conductivity/TDS/Salinity/Temp Meter
![]() |
CD5 series are used to
measure conductivity, total dissolved solid, salinity and temperature of
solution. Microprocessor-Based: CD5 series has built-in high performance CPU, it can work about 200 hours continuously with 9 volt battery. Single Point Push-Button Calibration: The meter with single point calibration function, it is permitted to use standard conductivity solution, you need only set conductivity value of the calibration solution at 25℃ and immerse conductivity electrode into solution, then press ENTER key, the meter will be calibrated automatically. Auto Standard Solution Recognition: In calibration, the meter will display ERROR if you use conductivity solution by mistake. Auto-Ranging for Conductivity: The meter with auto-ranging function when measure conductivity or total dissolved solid. After electrode immersed in solution, CD5 series will fast response and convert range. Auto Temperature Compensation: The meter will recognize the temperature sensor automatically and measure temperature after temperature sensor connected to the host. If the conductivity electrode connected to it, the meter will enter automatic temperature compensation. Adjustable Temperature Coefficient: Solution contained different ions usually have different temperature coefficient,CD5 series can be set in the range of 0 and 3.9% per centigrade degree. |
|
|
|
Adjustable Cell Constant: When measure solution with higher or lower concentration, you should choose different constant of conductivity electrode. The meter with three cell constants for your choose, it can save the measured value for different constant electrode separately. After setting the constant, you needn't calibrate it again when replacing a new electrode. Adjustable TDS Coefficient: According to the theory of electrical conductivity, you need estimate TDS coefficient when measure total dissolved solid of solution.CD530/540 can be set in the range of 0.01 to 1.00, which can ensure accuracy of measured value. Hold Function: The meter with hold function, press MEAS/HOLD key, the meter momentarily freezes reading for easy viewing. Message Indicator: The meter with operational message indicator. When you need setup or measurement, the message indicator will help you what you can do and how do it. You can set parameter or select functions under it's guide. Save Data: The meter can save 64 data sets, press SAVE key, and the meter will store current measured value, serial number, date, time and other information. Output Data: The data can be sent to computer through USB Communication interface, you can print out test report via software. |
Model | CD520 | CD530 | CD531 | CD540 |
Conductivity Range | 0~1.999, 19.99, 199.9, 1999uS/cm, 19.99, 199.9mS/cm | |||
Conductivity Accuracy | ±0.5% F.S | ±0.5% F.S | ±0.5% F.S | ±0.5% F.S |
TDS Range | --- | 0~Max.200ppt | --- | 0~Max.200ppt |
TDS Accuracy | --- | ±1% F.S | --- | ±1% F.S |
TDS Conversion Factor | --- | 0.01~1.00 | --- | 0.01~1.00 |
Salinity Range | --- | --- | 0.00~5.00% | 0.00~5.00% |
Salinity Accuracy | --- | --- | ±0.05% | ±0.05% |
Temperature Range | 0~100oC | |||
Temperature Accuracy | ±1oC | |||
Calibration Points | 1 Point | |||
Calibration Solution | 146.6uS/cm, 1408uS/cm, 12.85mS/cm | |||
Temperature Compensation | 0~50oC | |||
Temperature Coefficient | 0~3.9%/oC | |||
Cell Constant | K=0.1, 1, 10, adjustable | |||
Memory | 64 data sets | |||
Display | 4.3' LCD | |||
Output |
USB Communication interface |
|||
Power Requirements | 9V Battery | |||
Battery Life | Approx. 200 hours of continuous use | |||
Dimensions | 185(L)mm×88(W)mm×32(H)mm | |||
Weight | 300g |
CD950
Conductivity/TDS/Salinity/Temp Meter
![]() |
CD950 are used to measure
conductivity, TDS (Total
Dissolved Solid), salinity and temperature of solution. Feature: Microprocessor-Based Single point push-button calibration Auto standard solution recognition Auto-ranging for conductivity Auto temperature compensation Adjustable temperature coefficient (0~3.9%) Adjustable cell constant (K=0.1,1,10) Adjustable TDS coefficient |
|
|
Model | CD950 |
Conductivity Range | 0~1.999, 19.99, 199.9, 1999uS/cm, 19.99, 199.9mS/cm |
Conductivity Accuracy | ±0.5% F.S |
TDS Range | 0~Max.200ppt |
TDS Accuracy | ±1% F.S |
Salinity Range | 0.00~5.00% (50ppt) |
Salinity Accuracy | ±0.05% (0.5ppt) |
Resistivity Range | 0 to 100MΩ |
Resistivity Accuracy | ±1% F.S |
Temperature Range | 0~100oC |
Temperature Accuracy | ±1oC |
Calibration Points | 1 Point |
Calibration Solution | 146.6uS/cm, 1408uS/cm, 12.85mS/cm |
Temperature Compensation | 0~50oC |
Temperature Coefficient | 0~3.9%/oC |
TDS Conversion Factor | 0.01~1.00 |
Cell Constant | K=0.1, 1, 10, adjustable |
Memory | 99 data sets |
Output |
USB Communication interface |
Power Requirements | DC9V, using AC adapters, 220VAC, 50Hz |
Dimensions | 210(L)mm×188(W)mm×60(H)mm |
Weight | 1.5kg |
KL-1385 & KL-1385L EC/CF/TDS
Waterproof Nutrient Meter
![]() |
1. Large and easy-to-read
LCD 2. Waterproof design to withstand wet environment 3. Measures 3 parameters including EC,CF,TDS using one electrode 4. Hold Function to saves measurements for convenient reading and recording Measuring range: EC: 0.00~19.99EC; CF: 0.0~199CF; TDS: 10~19990ppm Resolution: EC: 0.01EC; CF: 0.1CF; TDS: 10ppm Accuracy: ±2%F·S Operating Temperature: 0℃~50℃ ATC: 0℃~50℃ Power Supply: 4×1.5V(AG13) Dimensions: 185×38×38mm |
|
![]() |
Nutra Wand Accurate EC/CF/PPM Nutrient Meter RS-100B
![]() |
This meter is a new
generation of the "Nutra Wand". It has wider measuring range and higher
accuracy, with LCD display instead of analogue display. Automatic Off Display hold function Display illumination Switching among CF, EC, and PPM values 100% waterproof Measuring Range: 0-100CF; 0.0-10.0EC; 10-9990ppm Resolution: 1CF; 0.1EC; 10ppm Accuracy: ±2% FS Temp: 5-50°C (ATC) Calibration: One point at 6.7 EC Power supply: DC9v battery Display LCD with illumination, with hold function |
|
KL-2385 CF ECO stick - EC/CF/PPM
Nutrient Meter
![]() |
Technical Specifications: Range: 4-52CF; 280-3640ppm (EC x 700); 0.4-5.2EC; 200-3000ppm (ECx500) Resolution: 0.1 EC(1 CF); 70ppm 700; 50ppm 500 Accuracy: ±4% of reading Temperature Compensation: Automatic Operating Temperature: 0 - 50℃(32 - 122。F) Calibration: Factory Calibrated Power Source: 3×1.5V Alkaline Batteries Auto Sense: Auto On and Auto Off |
|
KL-1371 & KL-1372 Pen Type EC
Meter
![]() |
Order
No.: |
![]() |
![]() |
||
Model | KL-1371 | KL-1372 | ||
Range | 0~19.9EC | 0~19.99EC | ||
Resolution | 0.1 EC | 0.01 EC | ||
Accuracy | ±2% F·S | |||
Operating Temp | 0℃~50℃ | |||
ATC | 0℃~50℃ | |||
Power Supply | 4×1.5V(AG13) | 2×3V(CR2032) | ||
Dimension (mm) | 142×29×15 | 150×27×20 | ||
Weight | 51g | 46g |
KL-1361 & KL-1362 Pen Type CF
Meter
![]() |
Order
No.: |
![]() |
![]() |
||
Model | KL-1361 | KL-1362 | ||
Range | 0~100CF | |||
Resolution | 1CF | |||
Accuracy | ±2℅F·S | |||
Operating Temperature | 0℃~50℃ | |||
Power Supply | 4×1.5V(AG13) | 2×3V(CR2032) | ||
Calibration | 1 point | |||
Dimension(mm) | 142×29×15 | 150×27×20 | ||
Weight | 51g | 46g |
AP-2 AquaPro Water Quality EC
Meter
![]() |
FEATURES |
![]() |
COM100 EC/TDS/Temp Combo Meter
![]() |
Features
|
|
COM80 EC/TDS/Temp Combo Meter
![]() |
Features
|
|
Professional Conductivity Meter
DDS-307
![]() |
This precision meter is
for laboratory and can be used for measuring the conductivity of
distilled water, drinking water, industrial water and other liquid. Range: 0.001 ~ 200000μS/cm Scale 1: 0.001~2μS/cm Scale 2: 0.01~20μS/cm Scale 3: 0.1~200μS/cm Scale 4: 0.001~2ms/cm Scale 5: 0.01~20ms/cm Scale 6: 0.1~200mS/cm Accuracy: ±1% Full Scale ATC: 15~40℃ Power: DC9V 100mA Size: 208×200×76mm Weight: 390g |
![]() |
Professional Conductivity Meter
DDS-17
![]() |
Model |
DDS-17 |
![]() |
Measuring Range |
0~1.999x105us/cm |
|
Accuracy |
≤±1.5%F.S±1 digits |
|
ATC |
15~35℃ |
|
Power Supply |
220V 50Hz |
|
Environment |
Temp:5~40℃ RH<85% |
|
Dimensions |
240×158×100mm |
|
Weight |
950g |
Professional Conductivity Meter
DDSJ-308A
![]() |
Characteristics:
1.Double digits LCD display with big screen and blue back light, display conductivity value and temperature value 2.It can be used to measure conductivity, TDS, salinity and temperature. 3.Auto temperature compensation, auto calibration, auto range changing and electricity cutting off protection 4.Measurement results can be stored, deleted, consulted, printed. can store at most 50 sets of measurement data. 5.With RS-232 interface, Model TP-16 printer can be connected 6.With calibration function, can set electrode constant and TDS switching coefficient 7.Measuring ultrapure water with using K=0.01cm-1 titanium alloy electrode and sealing measuring cell 8.Connecting PC with the meter with selecting data soft Specifications: 1. Measurement range: Conductivity: 0-1.999 X 10uS/cm (can be divided into six ranges and can range changing automatically); 0-1.999uS/cm, 2.00-19.99uS/cm, 20.0-199.9 uS/cm, 200-1999uS/cm, 2.00-19.99mS/cm,20.0-199.9mS/cm TDS: 0-19900mg/L (can be divided into five ranges and can range changing automatically),0-10.00mg/L,10.0-100.0mg/L, 100-1000mg/L, 1.00-10.00g/L, 10.0-19.99g/L Salinity: 0.0-80ppt〔(0.0-8.00)%〕 Temperature: -5-105° C 2.Electrode constant, cm-1: 0.01; 0.1; 1.0; 10.0 3. Accuracy: Conductivity: ±0.5%(FS) ±1bit; Salinity: ±1.0ppt; Temperature: ±0.3°C ±1.bit 4. Stability: ±0.33%(FS) ±1bit/3h 5. The range of temperature compensation: 0-50° C |
![]() |
Professional Conductivity Meter
DDSJ-308F
![]() |
Characteristics:
1. It can perform measurement of conductivity, resistance, TDS, salinity and temperature. 2. It has functions of automatic temperature compensation, automatic switch of calibration, measuring range and frequency. Also, power- off protection function is included. 3. It supports calibration of cell constant and TDS factor. 4. It adopts dot-matrix LCD and backlight display and light-touch keys. 5. It can view, print and delete stored data. Up to 200 sets of measuring data can be saved. 6. It has USB interface. If matched with specific communication software, the meter can be connected with computer. 7. It can be used with titanium alloy electrode and sealing groove for measurement of high pure water. Specifications: Accuracy grade:0.5 1. Measuring range: Conductivity: 0.000us/cm ~199.9mS/cm; Resistance: 5.00Ω.cm~20.00MΩ.cm; TDS:0.000mg/L~99.9g/L; Salinity: 0.00~8.00% 2. Resolution: Temperature: 0.1°C 3. Accuracy: Conductivity:±0.5%(FS); Resistance:±0.5%(FS); TDS: ±0.5%(FS); Salinity: ±0.1%; Temperature: ±0.2°C 4. Manual/automatic Temperature compensation range: 0.0~40.0°C 5. Power supply: DC adapter (9V,DC,800mA,inside positive and outside negative) 6. Size: 280x215x92mm 7. Weight: 2kg |
![]() |
Professional Conductivity Meter
DDSJ-318
![]() |
Features 1. This conductivity meter can measure conductivity, resistivity, TDS (total dissolved solids), salinity and temperature of the current solution. 2. It applies microprocessor-based technology and functions as automatic temperature compensation, auto-calibration, auto measuring range switch can be supported. 3. The user can calibrate the electrode constant or TDS conversion coefficient. It supports two-point calibration. 4. The stored data can be displayed by graphics and can be viewed, printed and deleted. 5. This conductivity meter allows the user to review current measuring data and the last calibration data. 6. It contains three kinds of measuring modes: Continuous measurement, timed measurement and balance measurement which can meet different measuring requirements. 7. This conductivity meter uses a 5.7 inch large touch screen, RS-232 and USB interface. With data collecting software, it can be communicated with PC.
|
![]() |
Range | Conductivity | 0.055μS/cm~199.9mS/cm (full range measuring, no need to exchange electrode) |
Resistivity | 5.00Ω·cm~18.25MΩ·cm | |
TDS | 0.000 mg/L~100g/L | |
Salinity | 0.00~8.00% | |
Temperature | -5.0~135.0℃ | |
Accuracy | Conductivity | ±0.5%FS |
Resistivity | ±0.5%FS | |
TDS | ±0.5%FS | |
Salinity | ±0.1% | |
Temperature | ±0.3℃ | |
Resolution | Conductivity | 0.001μS/cm |
Resistivity | 0.01Ω·cm | |
TDS | 0.001 mg/L | |
Salinity | 0.01% | |
Temperature | 0.1℃ | |
Temp compensation | Manual/Auto -5.0~135.0℃ | |
Temp coefficient | Adjustable | |
Calibration | May calibrate electrode constant or TDS switch coefficient. Support two-point calibration | |
Measuring mode | Continuous, timed, balance | |
Data storage | 1500 data with time-and-date for GLP compliance(to display measuring result in diagram directly) | |
View, delete and print | Yes | |
Output | RS-232, USB | |
Software | 1.1DC | |
Power | Adapter (9V DC, 800mA) | |
Sipping package | 370x310x340mm, 4kg |
CD-208 Digital Conductivity
Controller
![]() |
Measuring Range:
0~1999us/cm, 0~199.9mS Accuracy: ±(1.5%+2 digits) after calibration Resolution: 1us, 0.1mS Set Range: 0~1000us, 0~100.0mS Environment Temperature: 0~50℃ Humidity<95% Power Supply: 220V±10℅ 50Hz±2℅ Dimensions: 150mm×85mm×40mm |
|
CD-308 Digital Conductivity
Controller
![]() |
Measuring Range:
0~1999us/cm, 0~199.9mS Accuracy: ±(1.5%+2 digits) after calibration Resolution: 1us, 0.1mS Set Range: 0~1000us, 0~100.0mS Environment Temperature: 0~50℃ Humidity<95% Power Supply: 220V±10℅ 50Hz±2% Dimensions: 160mm×102mm×40mm |
|
Dual TDS Monitor KL-761EC (HM
model DM-2EC)
![]() |
FEATURES |
|
•Highly
efficient and accurate due to its advanced microprocessor
technology. |
|
SPECIFICATIONS | |
1. Range: 0-9990µS 2. Accuracy: ±2% 3. Cable Length: 46" (including sensor), shielded cables 4. Sensor: Dual, 1/4" diameter for quick-connect fittings (model SP-3, included) 5. Digital Calibration: Digitally factory calibrated to 1413 µS. Re-calibration can be done separately for each line. 6. Power source: 2 x AA batteries 7. Battery life: Approx. 2 years 8. Size: 11.6 x 6.8 x1.8 cm (4.6 x 2.6 x .7in.) 9. Weight: 201.3 g (7.1 oz.) |
Conductivity Monitor CM-230
![]() |
This instrument is a
panel instrument for on-line monitoring of industrial process
conductivity. Range switch over and constant check can both be
freely set and adjusted through the operation component on the rear
panel; unique signal collecting and processing technology and
special thick film circuit are adopted to make measurement accurate
and operation stable; there are also other features such as
linearized data, automatic temperature compensation, not subject to
the length change of cable and maintenance-free. It’s an ideal
auxiliary instrument of various types of small pure water equipment.
|
![]() |
Measurement
range:
|
0~20
0~200
0~2000μS/cm
|
Accuracy
|
1.5% (FS)
|
Stability
|
±2 × 10-3
(FS) / 24h
|
Auxiliary
electrode
|
Plastic
structure; constant: 1.0cm-1
|
Temperature
compensation component
|
NTC
|
Medium
temperature
|
5~50℃
|
Thread
dimension
|
1/2″pipe
thread
|
Medium
pressure
|
0~0.5Mpa
|
Cable
composition
|
Quad cable,
copper mesh and foil shielded plastic jacket
|
Cable length
|
5m or on
other agreement (5~30m)
|
Temperature
compensation
|
Automatic
compensation, with 25℃ as the reference temperature
|
Display
|
3.5-bit LCD
|
Power supply
|
AC 220V
±10% 50Hz
|
Power
consumption
|
≤1W
|
Environment
conditions
|
(1)
Temperature: 5~50℃;
(2) Humidity: ≤85%RH
|
Dimensions
|
48 × 96 ×
100mm (height × width × depth)
|
Slot
dimensions for installation
|
45 × 91mm
(height × width)
|
Conductivity Monitor CCT-3320V (CM-230 new
version)
![]() |
This instrument is a
panel instrument for on-line monitoring of industrial process
conductivity. Range switch over and constant check can both be
freely set and adjusted through the operation component on the rear
panel; unique signal collecting and processing technology and
special thick film circuit are adopted to make measurement accurate
and operation stable; there are also other features such as
linearized data, automatic temperature compensation, not subject to
the length change of cable and maintenance-free. It’s an ideal
auxiliary instrument of various types of small pure water equipment.
|
|
Measurement
range:
|
0~20
0~200
0~2000μS/cm
|
Accuracy
|
1.5% (FS)
|
Stability
|
±2 × 10-3
(FS) / 24h
|
Auxiliary
electrode
|
Plastic
structure; constant: 1.0cm-1
|
Temperature
compensation component
|
NTC
|
Medium
temperature
|
5~50℃
|
Thread
dimension
|
1/2″pipe
thread
|
Medium
pressure
|
0~0.5Mpa
|
Cable
composition
|
Quad cable,
copper mesh and foil shielded plastic jacket
|
Cable length
|
5m or on
other agreement (5~30m)
|
Temperature
compensation
|
Automatic
compensation, with 25℃ as the reference temperature
|
Display
|
3.5-bit LCD
|
Power supply
|
AC 220V
±10% 50Hz
|
Power
consumption
|
≤1W
|
Environment
conditions
|
(1)
Temperature: 5~50℃;
(2) Humidity: ≤85%RH
|
Dimensions
|
48 × 96 ×
100mm (height × width × depth)
|
Slot
dimensions for installation
|
45 × 91mm
(height × width)
|
Conductivity Controller CM-230KL
![]() |
This instrument is a
panel instrument for on-line monitoring of industrial process
conductivity. Range switch over and constant check can both be
freely set and adjusted through the operation component on the rear
panel; unique signal collecting and processing technology and
special thick film circuit are adopted to make measurement accurate
and operation stable; there are also other features such as linearized data, automatic temperature compensation, not subject to
the length change of cable and maintenance-free. It has control
function, including setting of over limit of conductivity, and the
outputs are control contacts. It’s an ideal auxiliary instrument of
various types of small pure water equipment.
|
|
Measurement
range
|
0~20.00,
0~200.0,
0~2000,
0~9999μS/cm automatic switch, Temp.:0~100℃
|
Accuracy
|
±2% (FS)
|
Display mode
|
4 digit 0.56"
(14mm)
LED digital display
|
Auxiliary
electrode
|
K=1.00
plastic electrode (K=0.1 0~200.0μS/cm,
K=0.01 0~20.00μS/cm optional, plastic or stainless steel)
|
Thread
dimension
|
G1/2″ pipe
thread
|
Current Output
|
4~20mA
|
Relay Control
|
Single 1 high
point setting, contact capacity 3A/220V; 2 High Low points
setting (optional)
|
Temperature
compensation
|
Automatic
compensation 0~60℃
|
Power supply
|
AC220V
±10%; 50Hz or DC24V (optional)
|
Operation
pressure of conductance cell
|
0~0.5MPa
|
Cable length
|
5m or on other
agreement
|
Dimensions
|
48 x 96 x
100mm (height x width x depth)
|
Slot
dimensions for installation
|
45 x 91mm
(height x width)
|
Conductivity Controller
![]() |
Applications: Widely used for pharmacy, food, beverage, paper making, environment protection or chemical industries. |
|
Specifications: 1. Power supply: CCT-5320E: AC 220±10% CCT-5310E: AC 110±10% CCT-5300E: DC24V±4V 2. Conductivity Cell Constant: 0.10 (Optional); 1.00 (Standard range 0-2000us/cm); 5.00 (optional) (cm-¹) 3. Measurement Range: Conductivity 0.5μS/cm~10.00mS/cm; TDS: 0.25ppm~5.00ppt; Temp.: 0~50℃ (Temp. compensation component: NTC10K) 4. Resolution: Conductivity: 0.01μS/cm; 0.01mS/cm; TDS: 0.01ppm; Temp.: 0.1℃ 5. Accuracy: Conductivity: 1.5% (FS); TDS: 1.5% FS; Temp.: ±0.8℃ 6. Temp. Compensation Range: 0~50℃ (with25℃ as standard) 7. 4~20mA: 1)Channels: Single channel, isolated; 2) Characteristics: Reversible, fully adjustable, instrument / transmitter mode for selection; 3) Loop resistance: 400Ω max, DC24V; 4) Accuracy: ±0.1mA 8. Control contacts: 1) Channels: Single channel; 2) Relay contacts: SPDT; 3) Load capacity: AC 220V/3A Max; AC 110V/5A Max; DC 24V/3A Max 9. Work Environment: Temp: 0~50℃, relative humidity: <85%RH, 10. Storage Environment: Temp: -20~60℃; relative humidity: <85%RH 11. Dimensions: 96 x 96 x 105mm 12. Hole size: 91 x 91mm (H x W) 13. Installation: Panel mounted, fast installation |
|
Conductivity cell selection CON3133-13: (0.1cm-¹) sanitary grade 316L sensor used for RO pure water measuring, optional; CON1134-13: (1.0 cm-¹) plastic sensor used for industry water, tap water and cooling water measuring; CON2134-13: (1.0 cm-¹) graphite sensor used for municipal and industrial pure water measuring, optional; CON2135-13: (5.0 cm-¹) graphite sensor used for waste water and high salinity water measuring Note: CON1134-13 (1.0 cm-¹) can’t be used for food, beverage, medical or sanitary industries. |
Panel Mount TDS Controller PS100
![]() |
FEATURES •Monitors and controls TDS levels for high output commercial systems. •Large, bright L.E.D. display. •An alarm will sound if the TDS level rises above the user-set level. •Installs easily in minutes. •Includes one sensor probe (at no extra cost). •Protective cover also available (sold separately) SPECIFICATIONS Range: 0 - 999ppm Accuracy: ±2% Conversion Factor: NaCl (avg. 0.5) Resolution: 1 PPM ATC: Yes (1 - 65 degrees Celsius) Calibration: Adjustable (manual) Setting: Controlled by on-screen up/down buttons Relay Control: The unit will open or close a circuit via dry contacts when the ppm level reaches or exceeds the control setting (simple switch). It can be used to control a pump, solenoid valve or other device. Relay Voltage: 5V Alarm: Optional steady beep (set by user) Display: Bright 5/8" L.E.D. display Probe: 1/2" bushing, 3 meter (9.8 ft) shielded cable Power supply: AC 110V / AC 220V Dimensions: 7.2 x 7.2 x 10.2 cm (2.8 x 2.8 x 4 in.) Monitor Weight: 476 g (1 lb .8 oz) Total Weight: 680.4 g (1 lb 8 oz) |
|
Conductivity/TDS Controller PSC-150
![]() |
FEATURES
|
![]() |
SPECIFICATIONS EC Range: 0-9999 µS; TDS Range: 0 - 5000ppm Temperature Range: 1-75°C; 33-167 °F Accuracy: ±2% Conversion Factor: NaCl (avg. 0.5) Resolution: 0.1µS/ppm (0-999); 1µS/ppm (1000-9999) ATC: Yes (1 - 65°C) Calibration: Adjustable (manual) Setting: Controlled by on-screen up/down buttons Relay Control: The unit will open or close a circuit via dry contacts when the ppm/µS level reaches or exceeds the control setting (simple switch). It can be used to control a pump, solenoid valve or other device. Relay Voltage: 5V Alarm: Optional steady beep (set by user) Display: Bright 5/8" L.E.D. display Probe: 1/2" bushing, 3 meter (9.8 ft) shielded cable Power supply: AC 110V / AC 220V Dimensions: 7.2 x 7.2 x 10.2 cm (2.8 x 2.8 x 4 in.) Monitor Weight: 476 g (1 lb .8 oz) Total Weight: 680.4 g (1 lb 8 oz) |
![]() |
Optional Protective Cover |
TDS/EC Controller with 4-20mA
Output PSC-154
![]() |
FEATURES •Monitors and controls TDS/EC levels for high output commercial systems. •Large, bright L.E.D. display. •4-20mA output signal can connect to a PLC to record values. •An alarm will sound if the TDS /EC level rises above the user-set level. •A switch will control a device based upon the set point. •On-screen temperature display (C/F). •Installs easily in minutes. •Includes one sensor probe (at no extra cost). •Protective cover also available (sold separately) |
![]() |
SPECIFICATIONS EC Range: 0-9999 µS; TDS Range: 0 - 5000ppm Temperature Range: 1-75°C; 33-167 °F Accuracy: ±2% (of the reading) Conversion Factor: NaCl (avg. 0.5) Resolution: 0.1µS/ppm (0-999); 1µS/ppm (1000-9999) ATC: Yes (1 - 65°C) Calibration: Digital by push button Set-Point: Single point, controlled by on-screen up/down buttons (to any point within the range) Relay Control: The unit will open or close a circuit via dry contacts when the ppm/µS level reaches or exceeds the control setting (simple switch). It can be used to control a pump, solenoid valve or other device. Relay Voltage: 5V Output Signal: Digital 4-20mA Output Accuracy (mA): ±1% Alarm: Optional steady beep (set by user) Display: Bright 5/8" L.E.D. display Probe: 1/2" bushing, 3 meter (9.8 ft) shielded cable Power supply: AC 110V / AC 220V Dimensions: 7.2 x 7.2 x 10.2 cm (2.8 x 2.8 x 4 in.) Monitor Weight: 476 g (1 lb .8 oz) Total Weight: 680.4 g (1 lb 8 oz) |
![]() |
Optional Protective Cover |
CIC-152 Dual Control
Dosing/Injection TDS/EC Controller
![]() |
FEATURES •Monitors and controls dosing or injection systems. •Large, bright tri-color L.E.D. display. •Two adjustable set points keep TDS levels within a range (maximum and minimum TDS/EC levels). •Minimum and maximum control points will activate relay controls via switching dry contacts. •The CIC-152 can control two different devices (e.g., a pump and a valve). •Two alarms (maximum and minimum levels) can be set independently of the control points. •Digital calibration. •On-screen temperature display. •On-screen range & control indicator lights (green, yellow or red) •Installs easily in minutes. •Includes one sensor probe (no extra cost) •Protective cover also available (sold separately) •Available with the NaCl conversion factor (model CIC-152) or the 442TM conversion factor (model CIC-152-4) |
![]() |
SPECIFICATIONS TDS Range: 0 - 5000ppm (CIC-152): 0 - 8500ppm (CIC-152-4) EC Range: 0 - 9999µS Temperature Range: 1-80oC; 33-176oF Accuracy: ±2% (of the reading) Resolution: 0.1 ppm (0-999); 1 ppm (1000-9999) ATC: Yes (1 - 80 degrees Celsius) Calibration: Digital (by push button) Factory Calibration: 1413 µS Set Points: Adjustable by push button. Control Point 2: Maximum TDS Limit. Control Point 1: Lower TDS Level. Relay Control: The unit will transmit an analog signal (simple switch) via open or closed contacts to a device (e.g. pump/valve) when the ppm/µS level reaches the maximum TDS/EC limit (Control Point 2) or the minimum TDS/EC limit (Control Point 1). The contacts are switched back to the normal position once the TDS returns to the acceptable range. Relay Voltage: 5V (attached devices must have their own power supply) Alarm: Two independent alarms (set by user) Display: Bright 5/8" L.E.D. display Probe: 1/2" bushing, 3 meter (9.8 ft) shielded cable (model SP-1-PSC) Power supply: AC 110V / AC 220V Dimensions: 7.2 x 7.2 x 11.1 cm (2.8 x 2.8 x 4.4 in.) Monitor Weight: 476 g (1 lb .8 oz) Total Weight: 680.4 g (1 lb 8 oz) |
Conductivity/TDS/Resistivity/Temp.
Transmitting Controller CCT-8301A
![]() |
Applications and
features 1) With 32 bit processor as the core of the powerful kernel and operating system, make products to IT new era. 2) Using advanced modulus hybrid technology, intelligent measure range automatically measurement switch 3) Language man-machine interface, Guided operation menu, Humanized design process 4) TFT320×240 color LCD, Chinese/English language, multi parameter display in one screen 5) Grading permission password protect function, prevent noncertified person freely revise the engineering parameter when log in. 6) LCD background lighting can select long time lighten or delay sleep, fit low carbon fashion. |
|
Conductivity Cell Type | 10.00cm-¹ (optional) | 1.000cm-¹ (standard) | 0.100cm-¹ (optional) | 0.010cm-¹ (optional) | |
Range | Conductivity | 500~100000us/cm (100ms/cm) | 1.0~10000us/cm | 0.5~200us/cm | 0.05~18.25MΩ·cm |
TDS | 250~50000ppm | 0.5~50000ppm | 0.25~100ppm | ||
Temp. | 0~180℃ (Sensor PT1000) | ||||
Resolution | Conductivity: 0.01us/cm, 0.01ms/cm; Resistivity: 0.01MΩ·cm; TDS: 0.01ppm; Temp.: 0.1℃ | ||||
Accuracy | Conductivity/TDS: 1.5% F.S.; Resistivity: 2.0%; Temp.: ±0.5℃ | ||||
ATC | 25℃/90℃ | ||||
Output | 4-20mA | ||||
Communication | RS485, Modbus RTU agreements | ||||
Power | DC24V | ||||
IP Grade | IP65 | ||||
Size | 96 x 96 x 94mm | ||||
Slot Size | 91 x 91mm | ||||
Installation | Panel |
RO System Conductivity Controller
ROC-2313
![]() |
1. Power voltage: AC 220V±15%
50Hz, Power consumption: ≤3W
2. Environment
conditions: temperature: 0~50℃; humidity: ≤85%RH
3. Measuring
range: 0~200μS /cm; accuracy: 1.5 level
4. Load capacity
of output contact: 3A/250V AC (the magnetic valve should be
driven through intermediate relay)
5. Operation
pressure of conductance cell: 0~0.5Mpa
6.Medium
temperature:5~50℃
7.Temperature
compensation: automatic temperature with 25℃ as reference
temperature
8. Distance of
measuring range: less than 30m (the ex-factory configuration of
electrode cable is 5m unless there is a special agreement)
9. Display mode: 3
1/2-digit LED digital display
10.
Electrode selected: 1.0cm-1
11. outline
dimensions: 96×96×110mm (height×width×depth)
12.meter board
hole: 92×92mm (height×width)
|
|
The instrument is a combined control instrument of a reverse osmosis controller and an on-line conductivity instrument. It can perform the operation test, status control and on-line monitoring of water quality conductivity (combining PLC controller and conductivity meter). It takes multiple anti-interference measures, adopts unique process flow and graphical control panel with LED indicator lamp embedded, the interface is friendly; menu-driven operation is used, multiple groups of parameters can be set and modified, the requirements of automatic operation are met. |
KL-5100 & KL-5200 Conductivity
Transmitter
![]() |
Performance features 5100 is an integration mode conductivity transmitter. 5200 is a fission mode conductivity transmitter. They can meet long distance measurement of water solution conductivity in the industrial processes. The all sealed shell design meet the IP65 defending technology grade , can adapt to the wet environment .The any transferable 4~20mA isolated current signal can realize the operation mode of meter/transmitter by change the connection mode. Technical Specification Conductivity measurement range: Electrode constant 0.1cm-1 : 0~20μS/cm, 0~200μS/cm (optional) Electrode constant 1.0cm-1 : 0~20μS/cm, 0~200μS/cm 0~2000μS/cm (optional) Electrode constant 10.0cm-1 : 0~200μS/cm, 0~2000μS/cm 0~20mS/cm (optional) Temperature measurement range :0~50℃ ![]() Accuracy:1.5%(FS) Stability: ±2×10-3 (FS)/24h Signal output : isolate , transferable 4~20mA current , the optional output mode of meter/transmitter Power supply: DC 24V±10% Temperature of measured solution: 5~50℃ Defending types :IP65 defending grade The max circulative resistance : DC 24V@600Ω Display mode : Conductivity : 3.5bit LCD digital display , Temperature : 3bit digital display Outline dimensions: 130×70×50mm (height×width×depth) Installation mode: pipeline installation(5100), plane installation(5200). |
HM AP-1 AquaPro
Water Quality TDS Meter
![]() |
FEATURES Measures total dissolved solids (TDS) and temperature. Automatic Temperature Compensation (ATC) Water-resistant housing Measurement Range: 0-5000ppm Digital Calibration (push button) Auto-off function, data-hold function and low-battery indicator. Display: large and easy-to-read LCD screen includes simultaneous temperature reading. Factory Calibrated: The AquaPro is calibrated with a 342 ppm NaCl solution. The meter can be recalibrated with digital calibration using the push buttons, rather than a screwdriver. Includes a cap and batteries Comes in a retail-oriented package SPECIFICATIONS TDS Range: 0-5000ppm (mg/L) Temperature Range: 0-80 °C; 32-176 °F Resolution: 1ppm; Temp. resolution is 0.1 °C/F Accuracy: +/- 2% Calibration: Digital calibration by push button. Housing: Water-resistant Power source: 1 x 3V button cell (CR2032) Dimensions: 15 x 2.8 x 1.3cm (5.9 x 1.1 x .5 inches) |
|
HM TDS Meters KL-730 (TDS-3) &
KL-731 (TDS-3 Temp, With Temp Display)
![]() |
|
![]() |
![]() |
HM TDS Meters (Total Dissolved
Solids) KL-740 & KL-741 (With Temp Display)
![]() |
FEATURES
Includes an internal digital thermometer (celsius). The smallest and lightest TDS meter available on the market. Hold Function - Saves measurements for convenient reading and recording. Auto-off function - Turns off meter after 10 minutes of non-use to conserve batteries. Dual Range - Measures from 0 - 999ppm, with a resolution of 1ppm. From 1000 to 9990ppm, the resolution is 10ppm, indicated by a blinking 'x10' image. Factory Calibrated: our meters are calibrated with a 342ppm NaCl solution. Meters can be recalibrated with a mini-screwdriver. Recommended for aquariums & aquaculture, horticulture & hydroponics, pools & spas and water cooler professionals. SPECIFICATIONS TDS Range: 0-9990ppm (mg/L) Temp. Range: 0-80 degrees Celsius Resolution: 1ppm, 1 degree Celsius Accuracy: +/- 2% ATC: Built-in sensor for Automatic Temperature Compensation of 1 to 50 degrees Celsius (33 to 122 degrees Farenheit) Power source: 2 x 1.5V button cell batteries (included) Battery life: 1000 hours of usage Dimensions: 14 x 2.3 x 1.5 cm (5.5 x .9 x .55 inches) Weight: 34g (1.2 oz) |
|
TDS Meters (Total Dissolved
Solids) KL-710
![]() |
|
|
TDS Meters (Total Dissolved
Solids) KL-711
![]() |
SPECIFICATIONS
TDS Range: 0-9990ppm (mg/L) Temp. Range: 0-80 degrees Celsius Resolution: 1ppm, 1 degree Celsius Accuracy: +/-2% ATC: Built-in sensor for Automatic Temperature Compensation of 1 to 50 degrees Celsius (33 to 122 degrees Farenheit) Power source: 2 x 1.5V button cell batteries (included) Battery life: 1500 hours of usage Dimensions: 153 x 31 x 23mm Weight: 77g |
|
Conductivity/TDS Meter
![]() |
Model |
HMT-1 | HMT-2 | HMT-3 | HMT-4 | HMT-5 |
![]() |
Range |
0~9990ppm
|
0~9990ppm
0~ |
0~9990us/cm
|
0~9990us/cm
0~ |
0~9990ppm;0~9990us/cm
0~ |
|
Accuracy |
±2%F.S
|
|||||
A T C |
0 ~
|
|||||
Auto Shut-off |
10 minutes
|
|||||
Power |
2×1.5v(LR44l)
|
|||||
Dimensions |
142×25×
|
|||||
Weight |
|
KL-139 TDS Meter
![]() |
Order No.: KL-139P (Platinum Probe) KL-139S (Stainless Steel Probe)
Technical
Specification: |
|
KL-139A
& KL-139B TDS Meter
![]() |
Model | KL-139A | KL-139B |
Measuring Range | 0~1999PPm(mg/L) | |
Accuracy | ±2℅F·S | |
Resolution | 1PPm(mg/L) | |
Display | 4-digital LCD | |
Environment | Humidity:≤95℅ | |
ATC | 0℃~50℃ | |
Power Supply | 4×1.5V(AG13) | |
Dimensions | 165×26×26(mm3) | 60×55×23(mm3) |
Weight | 63g | 60g |
|
Order
No.: |
|
![]() |
KL-139C
TDS Meter
![]() |
Order No.: KL-139CP (Platinum Probe) KL-139CS (Stainless Steel Probe) Measuring Range: 10~1990ppm Accuracy:±2% F.S. Resolution: 10ppm ATC: 0℃~50℃ Power Supply: 4×1.5V(AG13) Dimensions: 150mm×29mm×15mm Weight: 51g |
|
KL-9835
TDS Meter
![]() |
Order No.: KL-9835P (Platinum Probe) KL-9835S (Stainless Steel Probe) Measuring Range: 0~1999ppm Accuracy: ±2% Full Scale Resolution: 1ppm ATC: 0℃~50℃ Power Supply: 3×1.5V(AG13) Dimensions: 175mm×51mm×25mm Weight: 60g |
|
KL-1396 (Stainless Steel Probe)
KL-1396P (Platinum Probe)
Waterproof TDS and Tem.
Meter
![]() |
Technical Specification:
ppm | Temp(℃) |
![]() |
|
Measuring range |
0~19990ppm |
-50℃~70℃ |
|
Resolution |
10ppm |
0.1℃ |
|
Accuracy |
±2% F·S |
±1℃ |
|
Display |
4-digital LCD | ||
Environment |
Humidity≤95% | ||
Automatic Temperature Compensation |
0℃~50℃ | ||
Power Supply |
4×1.5V(AG13) | ||
Dimensions |
188mm×35mm×35mm | ||
Weight |
98g |
KL-1395 TDS Meter with Temp
Display
![]() |
Order No.: KL-1395P (Platinum Probe) KL-1395S (Stainless Steel Probe) Measuring Range: 0~1999ppm (mg/L); -50℃~70℃ Resolution: 1ppm (mg/L); 0.1℃ Accuracy: ±2% F.S.; ±1℃ Display: 4-digital LCD Environment: Humidity≤95% ATC: 0℃~50℃ Power Supply: 4×1.5V(AG13) Dimensions: 170×36×23(mm3) Weight: 98g |
|
KL-1393 TDS Meter
![]() |
Order No.: KL-1393P (Platinum Probe) KL-1393S (Stainless Steel Probe) Measuring Range:
0~19.99ppt |
|
KL-1393A & KL-1393B TDS Meter
![]() |
Model | KL-1393A | KL-1393B |
Measuring range | 0~19.99PPt | |
Accuracy | ±2%F·S | |
Resolution | 0.01PPt | |
Display | 4-digital LCD | |
Environment | Humidity≤95% | |
Automatic Temperature Compensation | 0℃~50℃ | |
Power Supply | 4×1.5V(AG13) | |
Dimensions | 165×26×26(mm3) | 60×55×23(mm3) |
Weight | 63g | 60g |
|
Order
No.: |
|
![]() |
KL-1393C TDS Meter
![]() |
Order No.: KL-1393CP (Platinum Probe) KL-1393CS (Stainless Steel Probe) Measuring Range:
100~10000ppm |
|
KL-1393 TDS Meter
![]() |
Order No.: KL-1393P (Platinum Probe) KL-1393S (Stainless Steel Probe) Measuring Range:
0-19.99ppt |
|
Filter Monitor FM-1
![]() |
The new Filter Monitor is an innovative inline combination timer and volumizer. The battery-powered FM-1 has five timers for a 5-stage system, as well as a water volumizer and programmable set-points and alarms for each function, all in a crisp, attractive housing. | |
FEATURES A five-stage filter monitor with five independent timers and a tri-color LED faucet indicator disc. Works on time (and volume for the FM-2) for up to five stages (can be less). The LED indicator disc will illuminate a green, yellow or red light when the water is turned on. The color indicates the percentage of elapsed time. Auto-Off function conserves battery power. The unit shuts off automatically after 5 minutes of non-use. The timer counts down in months or days (settings can be modified). Includes an audible alarm (beep). Modern design is perfect for any kitchen. Installs quickly and easily. SPECIFICATIONS Timer Range: 0-999 days/months Timer Modes: Days or months (default is months) Settings: One alert per stage, up to five stages Default Setting: 12 months Batteries: 2 x AA (included) Battery Life: approx. 18 months Base Unit Dimensions: 100 x 63 23 mm (4 x 2.5 x 0.9 in) Base Unit Weight: 119 g (4.2 oz.) (including batteries) Flow Switch Cable Length: 93 cm (36.6 in) Flow Switch Fitting Size: 1/4" Quick Connect LED Faucet Indicator Disc Cable Length: 92cm (36.25 in) LED Faucet Indicator Disc Dimensions:4.75cm (1-1/4") dia., 8cm (5/16") high |
![]() |
Filter Monitor FM-2
![]() |
The new Filter Monitor is an innovative system to alert when a filter needs to be changed via color-coded lights at the base of the faucet. The battery-powered FM-2 has five timers for a 5-stage system, as well as a water volumizer and programmable set-points and alarms for each function, all in a crisp, attractive housing. | |
FEATURES •A five-stage filter monitor with five independent timers and a tri-color LED faucet indicator disc. •Counts time and volume for up to five stages (can be less). •The LED indicator disc will illuminate a green, yellow or red light when the water is turned on. The color indicates the percentage of elapsed time and volume used. •Auto-Off function conserves battery power. The unit shuts off automatically after 5 minutes of non-use. •The timer counts down in months or days (settings can be modified). •The volumizer counts up in gallons or liters (settings can be modified). •Includes an audible alarm (beep). •Modern design is perfect for any kitchen. •Installs easily. •Includes the FMS-2 flow sensor. SPECIFICATIONS Timer Range: 0-999 days/months Timer Modes: Days or months (default is months) Volume Range 0-99999 Gallons / Liters Volume Modes: Gallons (default) or Liters Volume Accuracy: +/-1% (at typical flow rates of approx. 1.5 to 2.5 LPM; low and high rates may affect accuracy) Maximum Pressure: 150 psi Settings: One alert per stage, up to five stages Default Setting: 12 months Batteries: 2 x AA (included) Battery Life: approx. 18 months Base Unit Dimensions: 100 x 63 23 mm (4 x 2.5 x 0.9 in) Base Unit Weight: 119 g (4.2 oz.) (including batteries) Flow Sensor Cable Length: 93 cm (36.6 in) Flow Sensor Fitting Size: 1/4" Quick Connect LED Faucet Indicator Disc: Works with any non-air gap filter faucet LED Faucet Indicator Disc Cable Length: 92 cm (36.25 in) LED Faucet Indicator Disc Dimensions: 4.75 (1 1/4" in.) dia., 8 cm (5/16") high |
![]() |
Dual TDS Monitor KL-760 &
Changeable Probe KL-760P (HM model DM-1)
![]() |
FEATURES | ||
1. Displays TDS
levels of the feed water and product water with in & out
electrode probes. 2. Highly efficient and accurate due to its advanced microprocessor technology. 3. Auto-Off function conserves battery power. The unit shuts off automatically after 10 minutes of non-use. 4. Dual Range 0-9990ppm (From 0 - 999ppm the resolution is 1ppm. From 1000 to 9990ppm, the resolution is 10ppm, indicated by a blinking 'x10' image.) 5. Factory Calibrated -Recalibration is not necessary. 6. Comes equipped with John Guest Quick-Connect T-fittings as shown. 7. Installs quickly and easily. |
|
![]() |
SPECIFICATIONS | ||
|
Dual TDS Monitor KL-761 (HM model
DM-2)
![]() |
FEATURES |
|
|
|
SPECIFICATIONS | |
|
Dual TDS Monitor KL-761EC (HM
model DM-2EC)
![]() |
FEATURES |
|
•Highly
efficient and accurate due to its advanced microprocessor
technology. |
|
SPECIFICATIONS | |
1. Range: 0-9990µS 2. Accuracy: ±2% 3. Cable Length: 46" (including sensor), shielded cables 4. Sensor: Dual, 1/4" diameter for quick-connect fittings (model SP-3, included) 5. Digital Calibration: Digitally factory calibrated to 1413 µS. Re-calibration can be done separately for each line. 6. Power source: 2 x AA batteries 7. Battery life: Approx. 2 years 8. Size: 11.6 x 6.8 x1.8 cm (4.6 x 2.6 x .7in.) 9. Weight: 201.3 g (7.1 oz.) |
KL-RO22 Dual TDS Meter
![]() |
Technical
Specification Measuring Range: 0~1999ppm Resolution: 1ppm Accuracy:±2% Full Scale Automatic Temperature Compensation: 0~50℃ Power Supply: 4×1.5V (AG13) Dimensions: 60mm×55mm×23mm Weight: 98g |
|
HL-233 Level Controller
![]() |
Power Supply: 220V/50HZ or
110V/60HZ Power Consumption: 2Watts Size: 150 x 85 x 42mm Weight: 690g Environment: Temperature: 0-50ºC, Humidity 95% The electronic level controller with 2 sensors will automate aquarium water top off. We include two float switch sensors with our electronic water level controller. The first float switch sensor triggers the feed pump (sold separately) to maintain the desire water level. The second float switch sensor ensures dependability and offers over flow protection. Our water level controller can also be used to protect pump from running dry. It can be utilized in three ways. |
|
HL-233T Level Controller with Temperature
![]() |
Technical
Specification: |
|
PS-100 Panel Mount TDS
Controller
![]() |
Install the Panel Mount
Controller to constantly monitor TDS levels of water produced by a
high-output system. FEATURES •Monitors and controls TDS levels for high output commercial systems. •Large, bright L.E.D. display. •An alarm will sound if the TDS level rises above the user-set level. •Installs easily in minutes. •Includes one sensor probe (at no extra cost). •Protective cover also available (sold separately) |
![]() |
SPECIFICATIONS Range: 0 - 999ppm Accuracy: ±2% Conversion Factor: NaCl (avg. 0.5) Resolution: 1 PPM ATC: Yes (1 - 65 degrees Celsius) Calibration: Adjustable (manual) Setting: Controlled by on-screen up/down buttons Relay Control: The unit will open or close a circuit via dry contacts when the ppm level reaches or exceeds the control setting (simple switch). It can be used to control a pump, solenoid valve or other device. Relay Voltage: 5V Alarm: Optional steady beep (set by user) Display: Bright 5/8" L.E.D. display Probe: 1/2" bushing, 3 meter (9.8 ft) shielded cable Power supply: AC 110V / AC 220V Dimensions: 7.2 x 7.2 x 10.2 cm (2.8 x 2.8 x 4 in.) Monitor Weight: 476 g (1 lb .8 oz) Total Weight: 680.4 g (1 lb 8 oz) |
PS-200 Dual TDS Controller
![]() |
Install
the Dual TDS Controller to constantly monitor TDS levels of water
produced by a high-output system. Immediately know if the TDS levels
rise above an acceptable level. |
|
SPECIFICATIONS Range: 0 - 999ppm Accuracy: ±2% Conversion Factor: NaCl (avg. 0.5) Resolution: 1PPM ATC: Yes (1 - 65 degrees Celsius) Calibration: Adjustable Setting: Controlled by on-screen up/down buttons Relay Control: The unit will open or close a circuit via dry contacts when the ppm level (out line/line 2 only)reaches or exceeds the control setting (simple switch). It can be used to control a pump, solenoid valve or other device. (In line/Line 1 does not have a control function) Relay Voltage: 5V (simple switch) Alarm: Optional steady beep for Out line/Line 2 (set by user) Display: Bright 5/8" L.E.D. display 2 Probes: 1/2" bushing, 3 meter (9.8 ft) shielded cable Power supply: AC 110V / AC 220V Dimensions: 7.2 x 7.2 x 10.2 cm (2.8 x 2.8 x 4 in.) Monitor Weight: 476 g (1 lb .8 oz) Total Weight: 822.1 g (1 lb 13 oz) |
PS-202 Dual TDS Controller
![]() |
The PS-202
allows for continuous and simultaneous monitoring and control of TDS
levels on two water lines. |
|
SPECIFICATIONS Range: 0 - 999ppm Accuracy: ±2% Conversion Factor: NaCl (avg. 0.5) Resolution: 1 PPM ATC: Yes (1 - 65 degrees Celsius) Calibration: Adjustable Setting: Controlled by on-screen up/down buttons Relay Control: The unit will open or close a circuit via dry contacts when the ppm level of the output water (line 2) or input water (line 1) reaches or exceeds its control setting (simple switch). The PS-202 can be used to control one or two pumps, solenoid valves or other device. Relay Voltage: 5V Alarm: Steady beep for both lines Display: Bright 5/8" L.E.D. dual displays 2 Probes: 1/2" bushing, 3 meter (9.8 ft) shielded cable Power supply: AC 110V / AC 220V Dimensions: 9.4 x 9.4 x 12.5 cm (3.7 x 3.7 x 4.9 in.) Monitor Weight: 569.8 g (1 lb 4.1 oz) Total Weight: 938.4 g (2 lbs 1.1 oz) |
Water Electrolyzer WE-1
![]() |
Electrolysis of water is the decomposition of water (H2O)
into oxygen (O2)
and hydrogen gas (H2)
due to an electric current being passed through the water. |
|
Reverse Osmosis (RO) Program Controller AMX001
![]() |
Overview The controller is a collection of typical mode of operation of many small and medium-sized reverse osmosis system, the control of single technology is a direct replacement for the PLC, programmed operation, greatly simplifying the construction elements. Control panel graphics, image process embedded LED indicators display system status, intuitive. RO controller uses four of the five into work. |
|
Specifications
2. Output control: the inlet valve, flush valve, source pumps, high
pressure pump |