DIGITAL LUX METER
LX-9626
![]() |
Application: widely
used in electro-optical sources, research teaching, metallurgy building,
industry inspection as well as agriculture researching and illumination
control. Measuring range: 0-50000LUX 0-5000FC 3 RANGE: x1,x10,x100 Resolution: 1 Accuracy: ±5%n HOLD Band pass filter Overload indication: 1 Power supply: 4x1.5V AAA (UM-4) battery Battery indicator: low battery indicator Dimensions: 97x53x17mm Weight (not including probe): 183g |
![]() |
DIGITAL LUX METER
LX-9621
![]() |
Application: widely
used in electro-optical sources, research teaching, metallurgy building,
industry inspection as well as agriculture researching and illumination
control. Measuring range: 0-50000LUX 3 RANGE: x1,x10,x100 Resolution: 1 Accuracy: ±5%n HOLD Band pass filter Overload indication: 1 Power supply: 4x1.5V AAA (UM-4) battery Battery indicator: low battery indicator Dimensions: 97x53x17mm Weight (not including probe): 174g |
![]() |
DIGITAL LUX METER
LX-101
![]() |
Application: widely
used in electro-optical sources, research teaching, metallurgy building,
industry inspection as well as agriculture researching and illumination
control. Measuring range: 0-50000LUX 3 RANGE: x1,x10,x100 Resolution: 1 Accuracy: ±5%n HOLD Band pass filter Overload indication: 1 Power supply: 4x1.5V AAA (UM-4) battery Battery indicator: low battery indicator Dimensions: 97x53x17mm Weight (not including probe): 174g |
![]() |
DIGITAL LUX METER
LX-80
![]() |
SPECIFICATION: ♦ Displays environmental illuminance in LCD ♦ Large Range: 1~200,000lux ♦ Accuracy up to ± 4% ♦ Resolution: 1lux / 0.1Fc ♦ Use for visible light measurement ♦ Unit: Lux / Fc ♦ Range Selecting: AUTO or Manual ♦ MAX / MIN Modes for choosing ♦ Impact proof housing ♦ Auto power off conserves battery energy ♦ Data Hold function ♦ Built-in battery check & low battery icon display ♦ Complete with protective cap, and 9V battery |
|
DIGITAL LUX METER
AMF023
![]() |
SPECIFICATION: *Measuring range: 0~200000Lux, 0~185806Fc *Accuracy: ±3% (<10,000Lux); ±4% (>10,000Lux) *Response time: 0.5s *Photometric sensor: Silicon diode *Operating temperature and humidity: 0℃~40℃, 10%RH ~ 90%RH *Storage temperature and humidity: -20℃~50℃, 10%RH ~ 90%RH *Power:9Vbattery *Unit size:52.5*35.5*166mm *Net weight: 110.4g *LUX (Lux) / FC (footcandles) Unit *Selection function *After 5 minute auto power off *Backlight function *Maximum and minimum measurements *Automatic measurement function (AUTO) *Data rise and fall time is short *Low battery indication |
|
DIGITAL LUX METER
![]() |
Order No.: | AMA001 |
![]() |
|
AMA002 with 270° adjustable sensor | |||
SPECIFICATIONS: ●Double Parameter Measurement: Lux (lm/m²); foot candle (lm/ft²) ●Range: 0~30000 Lux; 0~2788.0 ftc ●Resolution: 1 Lux; 0.1 ftc ●Accuracy: ±4% ●Sample rate: 1 time/sec ●Auto power off: about 20 minutes ●Operating environment: 0~+50℃(32~+122°F), 0~80%RH ●Storage environment: -20~+60℃(-4~+140°F), 0~80%RH ●Special function: Auto power off with disable feature; Data hold; MAX MIN; Back light ●Power Supply: DC1.5V (AAA) x 3pcs ●Dimension:121(L) x 60(W) x 30(H)mm ●Weight: about 180g |
LUX
METER
LX1010B
![]() |
1. Display: 3 1/2 digits
LCD display, maximum reading; value display 1999 2. Accuracy: <10,000Lux:±4%rdg±0.5f.s; >10,000Lux:±5%rdg±10digits (Calibrated to standard incandescent lamp at color temperature 2856K) 3. Ranges:1~100,000Lux.(3 Ranges); 20,000Lux range: reading x10; 100,000Lux range: reading x100 4. Resolution: 1Lux 5. Repeatability: ±2% 6. Temperature Characteristic: ±0.1% ºC 7. Sampling time: 0.5 second 8. Reading locked function 9. Photo detector: one silicon photo diode with filter. 10. Dimensions: 106 x 57 x 26mm (photo detector); 130 x 72 x 30mm (meter body) |
|
DIGITAL LUX METER
LX1010BS
![]() |
3-1/2 digits 18mm LCD Range: 1~100,000Lux Accuracy: ≤10,000Lux, ±(4%rdg+10digit) >10,000Lux, ±(5%rdg+10digit) Resolution: 1Lux Repeatability: ± 2% Temperature Characteristic: ± 0.1%/℃ Sampling Time: 0.5 second Photo detector: one silicon photo diode with fliter Dimensions: 130Lx72Wx30H(mm) Over-input: Indication of “1” |
|
AMTAST
DIGITAL LUX METER
LX-90
Fast Response
![]() |
3-1/2 digits 18mm LCD Range: 1~100,000Lux Accuracy: ≤10,000Lux, ±(4%rdg+10digit) >10,000Lux, ±(5%rdg+10digit) Resolution: 1Lux Repeatability: ± 2% Temperature Characteristic: ± 0.1%/℃ Sampling Time: 0.5 second Photo detector: one silicon photo diode with fliter Dimensions: 130Lx72Wx30H(mm) Over-input: Indication of “1” |
|
DIGITAL LUX METER
LX1020BS
![]() |
3-3/4 digits 18mm LCD Range: 0.1~40,000Lux Accuracy: ≤10,000Lux, ±(4%rdg+10digit) >10,000Lux, ±(5%rdg+10digit) Resolution: 0.1Lux Repeatability: ± 2% Temperature Characteristic: ± 0.1%/℃ Sampling Time: 0.5 second Photo detector: one silicon photo diode with fliter Dimensions: 130Lx72Wx30H(mm) Over-input: Indication of “OL”. Peak hold. |
|
DIGITAL LUX METER
LX1330B
![]() |
3-1/2 digits 18mm LCD Range: 0.1~200,000Lux/0.01~20,000FC Over-input: Indication of “1” Accuracy: ≤20,000Lux, ±(3%rdg+10digit); >20,000Lux, ±(5%rdg+10digit) Resolution: 0.1Lux Repeatability: ±2% Temperature Characteristic: ±0.1%/℃ Sampling Time: 0.5second Photo detector: one silicon photo diode with filter. Dimensions: 160Lx79Wx43H(mm) Date hold, peak hold Display in Lux and FC switchable |
|
DIGITAL LUX METER
LX1332B
![]() |
1. Display: 3 1/2
digits LCD display, maximum reading; value display 1999 2. Range gear: 200Lux, 2,000Lux, 20,000Lux, 200,000Lux, 20FC, 200FC, 2,000FC, 20,000FC; 20,000Lux range: reading x10; 200,000Lux range: reading x100; 20,000FC range: reading x10 3. Accuracy:±(4%rdg+10); >20,000Lux/2,000FC:±5%rdg±10digits (Calibrated to standard incandescent lamp at color temperature 2856K) 4. Repeatability: ±2% 5. Temperature Characteristic: ±0.1%/ºC 6. Sampling time: 0.5 second 7. Photo detector: one silicon photo diode with filter. 8. Dimensions: 180L x 65W x 35Hmm 9. Reading locked function 10. Measuring probe can 270° whirl |
![]() |
5 IN 1
Environment Tester AMF035
![]() |
Features: 1. Rugged 5-in-1 environmental tester with tripod mount 2. Large dual LCD simultaneous display of Real-time Value and MAX/MIN/AVG/DIF(MAX-MIN) Value 3. Data Hold, MAX/MIN/AVG/DIF, Auto power off, Low Battery and Over Range indicators 4. Built-in low friction vane wheel improves accuracy or air velocity in CMM, CFM, m/s, km/h, FPM, knots 5. Built-in precision digital humidity and temperature sensor for fast response 6. Utilizes precision photo diode and correction filter for Cosine and color corrected light measurements 7. Sound Level measurement meets IEC61672 class 2 using A/C weighting and fast/slow sample rating modes |
|
|||
Specifications | Range | Resolution | Accuracy | |
Temperature | -10~60℃; 14~140℉ | 0.1℃; 0.1℉ | ±1℃; ±2℉ | |
Humidity | 20%~80% RH | 0.1RH | ±3.0% RH | |
Light | 0~50000LUX | 1LUX | ±(5.0%+10) | |
Anemometer | 0.4~20m/s | 0.1m/s | ±(3.0%+10) | |
1.4~72km/h | 0.1km/s | |||
1.3~65.7ft/s | 0.1ft/h | |||
0.8~38.9knots | 0.1knots | |||
Air Flow | 0~999900CMM | 0.1CMM | ||
0~999900CFM | 0.1CFM | |||
Sound Level | 30~130dB(A) | 0.1dB | ±1.5dB |
UV LIGHT METER
UV340B
![]() |
Measurable of UVA & UVB LSI-circuit use provides high reliability and durability 3 3/4 LCD display, maximum indication 3,999 Range: 0~40mW/cm² 3 range: 400μW/cm², 4,000μW/cm², 40mW/cm² UV sensor spectrum: 290~390nm Accuracy: ±(4%FS+2 digit) Sensor structure: The exclusive UV photo diode & UV color correction filter. Sampling Time: 0.5 second Operating Temperature: -10~40°C(14~104°F) Operating Humidity: 0~70%Rh Over-input: Indication of “OL”. Peak hold. |
|
UV LIGHT METER
UVA365
![]() |
*Professional, high quality UV light
meter *Measurable of UVA *UV detector spectrum: 320nm to 390nm. *Four range selection switchable. *Display: 3 3/4 LCD display, maximum reading 39990. *Measurement Range: 0-400mW/cm²; Four range selectable: 400μW, 4000μW, 40mW, 400mW (1000 μW/cm² =1 mW/cm²) *UV sensor spectrum: band pass 320nm ~ 390nm *Accuracy: ±(4%FS + 2dgt) Calibration under the standard UVA light & and compare; Special tested under the environment RF Field Strength less than 3V/M & frequency less than the 30 MHz only *Sensor structure: exclusive UV photo diode & UV color correction filter. *Sample Time: 2.5 times/s. *Over Range indication: ‘OL’ *Weight: 325g(include battery) *Operating Temperature & Humidity: -10℃ to 40℃(32℉-104℉) 0~70%Rh *Power Supply: DC 9V battery, 006P, MN 1604 (PP3) or equivalent. *Power Consumption: Approx. DC 2.7mA *Dimension: 165x50x32mm (photo detector); 160x78x43mm (meter body) |
![]() |
UVC LIGHT METER
UVC254
![]() |
Features: 1. Professional and quality UV meter 2. Narrow-band spectrum 248nm~262nm, 254nm peak wavelength 3. Large scale integrated circuit ensures high precision and stability 4. UV probe comprises of visible light insulation diaphragm, narrow-band optical filter and gallium arsenide sensor. 5. Shell of aluminium alloy probe is equipped with fixed screw holes, which facilitates to measure to properly install the probe with ease. 6. Width of measuring span, 1uW/cm2~39.99mW/cm2 Scope: The instrument is applicable to the measurement of UV radiation intensity in fields of sterilization, photoetching, water treatment, health care and breeding. Specifications: 1. Wavelength coverage: 248nm~262nm 2. Peak wavelength: 254nm 3. Irradiance measuring span: 3999uW/cm2, 39.99mW/cm2 4. Resolution ratio: 1uW/cm2 5. Parasitic light beyond ultraviolent band: <0.1% 6. Accuracy: ±5% +2 words 7. Sampling rate: 2.5 times per second 8. Overload display: “OL” 9. Weight: 350g (Battery, probe included) 10. Power supply: DC 9V (6F22 type) battery 11. Operating current: about 2.7mA 12. Dimension: body 160x78x43mm; Sensorφ40x35mm |
|
UV LIGHT METER
UV126A
![]() |
UV126A is Suited for Radiation intensity
measurement of UV light source, such as
Ultraviolet curing lamp,
Photolithography exposure, integrated
circuit photolithography etc. Specifications: 1).Accuracy: ± 10 % 2).Resolution: 0.01 mW/cm² 3).Response Wavelength: 320nm ~ 400nm; λp =365nm 4).Measuring range: 0-2000 mW/cm² 5).Probe size: 45mm*12.5mm (D*H) 6).Instrument size: 130mm * 70mm * 28mm (L*W*H ) 7).Length of the probe wire: 1m 8).power supply: 4 AAA alkaline batteries |
![]() |
UV LIGHT METER
UV126C
![]() |
UV126C is used to measure the UVC
ultraviolet intensity, special for
measuring Ultraviolet sterilization
lamp. Specifications: 1) Accuracy:±10% 2) Resolution: 0.1 uW/cm² 3) Response Wavelength: 230nm ~ 280nm, λp = 254nm 4) Measuring range: 0-200000 uW/cm² 5) Instrument size: 130mm * 70mm * 28mm (L*W*H) 6) Probe size:45mm*16mm (D*H) 7) The probe wire length: 1m 8) Power supply: 4 AAA alkaline batteries Characteristic: 1) Use special UVC sensor filter to eliminate the effects of UVA and UVB rays. 2) Power down without loss of the last measurement data |
![]() |
UV INTEGRATOR UV150
![]() |
The UV-Integrator 150 is a high quality
UV measuring instrument. It is widely
used to measure UV energy of different
light sources, especially on printing
machines. It is ideal to ensure quality
control of printing and drying
processes. Spectral Range: UV 250~410nm (peak at 330nm) Measuring range: 0~5,000 MW/CM² Display Range: 0~999,999 MJ/CM² Power Source: 3.6V Battery Power consumption: 100uA Battery service life: 10,000 hours Dimensions: 3.5" (90mm) Diameter x 0.5" (12mm) height Weight: 150g |
![]() |
Solar Power Meter
SM206
![]() |
Features: 1. Selectable from two units: W/M² and Btu 2. Peak hold function 3. Data hold function 4. Measure directly without adjustment 5. Steadily measure for a long period Specifications: 1. Resolution: 0.1W/M², 0.1Btu/(ft2-h) 2. Error range: ±10W/M²; ±3Btu/(ft2-h) or ±5% of the measured value 3. Temperature error: ±0.38W/M²/ºC; ±0.12Btu/(ft2-h)/ºC; deviation at 25ºC 4. Display: 3-3/4 LCD display, maximum displayed numerical value 3999 4. Shift: <±3% /year 5. Overload display “OL” 6. Range: 0.1-399.9 W/M², 1-3999 W/M², 0.1-399.9 Btu/(ft2-h), 1-3999 Btu/(ft2-h) 7. Sampling time: 0.5 second 8. Operation temperature and humidity: 0°C to 50°C; <80%RH 9. Storage temperature and humidity: -10°C to 60°C; <70%RH 10. Dimensions and weight: 132 x 60 x 38mm 11. Weight: approx. 150g 12. Battery needed: 9V battery |
|